Nutrition 2007; 23(5):412-8

Réka Kegyes Bozó, dietitian; Zsuzsanna Lelovics, dietitian

Introduction:

  • Heart failure is characterized by fluid disturbances. Changes in volume in the clinical practice are evaluated with fluid balance and weight measurements, but these do not reflect compartmental changes.
  • Integrity of the cells can be characterized by the ratio of measured impedance values at 200 kHz and 5 kHz → Illness Marker (IM).
  • Tracking IM over time → can be used as fluid distribution indicator.
  • Multifrequency bioimpedance analysis may provide insight into the compartmental changes.
  • Multifrequency bioimpedance can be used in altered fluid distribution.

Aims: To describe the body composition of heart failure patients to explore the potential clinical role of IM in heart failure.

Methods: 

  • Randomly selected in-patients, who gave informed consent.
  • Body weight and height measured.
  • Heart echocardiography done by experts.
  • Bioimpedance measurements done with Bodystat Quadscan 4000.

Results: 

  • 35 patients were studied. Gender distribution: 57.1% men, 42.9% women, no significant difference according to functional status.
  • Presence of Diabetes mellitus: 31.4%, hypertension 57.1%. No significant difference according to functional status (NYHA).
  • Mean systolic function (EF) of the heart: 37%±13%
  • Strong, significant correlation (r=0.51; p=0.002) between ECW/ICW and IM. Strong, significant correlation (r=0.56; p=0.0005) between ECW and heart functional status. Strong, significant correlation (r=0.56; p < 0.001) between ICW and functional status.
  • Alterations in ECW and ICW compared to the normal values correlate strongly, negatively with functional status (r=0.55; p < 0005 and r=0.53; p < 0.001, respectively).

Conclusions:

  • Patient population is obese.
  • Bioimpedance measurements can distinguish between high fat content of the body and/or fluid overload.
  • Significant differences are present according to the functional status in body water spaces and Illness Marker.
  • There is a trend in the measured impedance data towards lower values in more severe cases. The significant difference detected in the difference between the measured impedance values reflects the clinical situation.
  • Illness Marker and BIA can be used to track changes occuring during the course of the disease.
  • The correlations between the body water spaces and IM and functional class show the potential clinical role of IM.

Download paper - Preliminary results for use of Illness Marker in heart failure patients